RP1007 Errors


Beep Errors

RP1007
Beep Pattern Description
1 beep every 2 sec
2 beeps every 2 sec
3 beeps every 2 sec
4 beeps every 2 sec
5 beeps every 2 sec Primary Op Stuck Limit or Open Motor Circuit
6 beeps every 2 sec Secondary Op Stuck Limit or Open Motor Circuit
1 beep then 2 beeps every 2 sec Master Terminal Red/Blk Short if motor test pass or
Arm Motor Short if motor test fails
2 beeps then 3 beeps every 2 sec Secondary Terminal Red/Blk Short if motor test pass or
Arm Motor Short if motor test fails
1 beep every 10-20 sec
2 beeps every 10 sec Motor Fault
Continuous Uninterrupted Alarm, No Ops Double Obstruction
Gate Stops and Reverses (up to full cycle) Obstruction
Power Up Beeps or Clicks upon Activation, No Ops

Blink Errors

If the alarm is not functional, the blink may actually be indicating a beep error instead
RP1007
Blink Pattern Description
1 blink every 2 sec Cycle Input Short - remove wire(s) from CYCL to resolve
2 blinks every 2 sec Safety Input Short - remove wire(s) from SAFE to resolve
3 blinks every 2 sec Exit Input Short - remove wire(s) from EXIT to resolve
4 blinks every 2 sec Shadow Input Short - remove wire(s) from SHDW to resolve
5 blinks every 2 sec Close Edge Input Short - remove wire(s) from EDGE to resolve
4 blinks every 2 sec Open Edge Input Short - remove wire(s) from EDGE to resolve
Charge LED flashing rapidly
Charge LED flashing
Charge LED off
D17 LED (under S4 button) flashing Power On (not error)