R5211-01 & R5211-02 Errors


Beep Errors

R5211-01 & R5211-02
Beep Pattern SL2000B, SL2200B, GPX-SL25, LPA13, LPS
1 beep every 2 sec Master Limit Switch (both have closed circuit at same time)
2 beeps every 2 sec Secondary Limit Switch (both have closed circuit at same time)
5 beeps every 2 sec Current Sensing Fault / Faulty Board
1 beep then 2 beeps every 2 sec Master Terminal Red/Blk Short if motor test pass
or Motor Short if motor test fails
1 beeps then 3 beeps every 2 sec Secondary Terminal Red/Blk Short if motor test pass
or Motor Short if motor test fails
1 beep every 10-20 sec
Continuous Uninterrupted Alarm, No Ops
Power Up Beeps or Clicks upon Activation, No Ops

Blink or Visual Errors

R5211-01 & R5211-02
Blink Pattern SL2000B, SL2200B, GPX-SL25, LPA13, LPS
1 blink every 2 sec Cycle Input Short
Remove wire(s) from CYCLE to resolve
2 blinks every 2 sec Safety Input Short
Remove wire(s) from SAFETY to resolve
3 blinks every 2 sec Exit Input Short
Remove wire(s) from EXIT to resolve
4 blinks every 2 sec Shadow Input Short
Remove wire(s) from SHADOW to resolve
5 blinks every 2 sec Close Edge Input Short
Remove wire(s) from CLOSE to resolve
6 blinks every 2 sec Open Edge Input Short
Remove wire(s) from OPEN to resolve
Gate Stops and Reverses