| R5211-01 & R5211-02 | |
|---|---|
| Beep Pattern | SL2000B, SL2200B, GPX-SL25, LPA13, LPS |
| 1 beep every 2 sec | Master Limit Switch (both have closed circuit at same time) |
| 2 beeps every 2 sec | Secondary Limit Switch (both have closed circuit at same time) |
| 5 beeps every 2 sec | Current Sensing Fault / Faulty Board |
| 1 beep then 2 beeps every 2 sec | Master Terminal Red/Blk Short if motor test pass or Motor Short if motor test fails |
| 1 beeps then 3 beeps every 2 sec | Secondary Terminal Red/Blk Short if motor test pass or Motor Short if motor test fails |
| 1 beep every 10-20 sec | Low Battery |
| Continuous Uninterrupted Alarm, No Ops | COUNT ERROR or Double Obstruction |
| Power Up Beeps or Clicks upon Activation, No Ops | Power Issue - Bad: Fuse, Battery, Switch, or Connection |
| R5211-01 & R5211-02 | |
|---|---|
| Blink Pattern | SL2000B, SL2200B, GPX-SL25, LPA13, LPS |
| 1 blink every 2 sec | Cycle Input Short Remove wire(s) from CYCLE to resolve |
| 2 blinks every 2 sec | Safety Input Short Remove wire(s) from SAFETY to resolve |
| 3 blinks every 2 sec | Exit Input Short Remove wire(s) from EXIT to resolve |
| 4 blinks every 2 sec | Shadow Input Short Remove wire(s) from SHADOW to resolve |
| 5 blinks every 2 sec | Close Edge Input Short Remove wire(s) from CLOSE to resolve |
| 6 blinks every 2 sec | Open Edge Input Short Remove wire(s) from OPEN to resolve |
| Gate Stops and Reverses | COUNT ERROR or Double Obstruction |